CODA-500, Automatic COD Monitor, HORIBA

CODA-500 Horiba

The CODA-500 is HORIBA's latest automatic on-line COD monitor based on the fully automated potassium permanganate method at 100 °C in accordance with JIS K 0806 — the standard method for regulatory compliance monitoring at industrial wastewater discharge points. Available in three model variants (acidic, alkaline, and acidic with reagent cleaning), it delivers COD measurement across ranges from 0–20 mg/L to 0–2000 mg/L with potentiometric titration at constant current and micro syringe precision. Reagent consumption has been reduced to 1/10 of previous models, and the reagent replacement interval extended to one month or more, significantly lowering life cycle costs.

Add to bag

The CODA-500 is HORIBA's automatic COD monitor for continuous on-line measurement of chemical oxygen demand in industrial wastewater, based on the fully automated potassium permanganate method at 100 °C in accordance with JIS K 0806. Three model variants are available and selected at the time of order: CODA-500-A uses the acid potassium permanganate method (JIS K 0806) suitable for most industrial wastewater; CODA-500-B uses the alkaline potassium permanganate method, which is not influenced by chloride ion concentration and is recommended for high-chloride samples; CODA-500-C combines the acid method with a reagent cleaning function for operation in samples with high chloride ion concentrations (up to 100× full-scale value). Measurement is performed by potentiometric titration at constant current using a micro syringe for precise reagent delivery and direct heating at 100 °C. A key improvement over previous models is a 1/10 reduction in reagent consumption per measurement run, extending the reagent replacement interval to one month or more and significantly reducing life cycle operating costs. COD load calculation, 1-year data memory, USB data export, RS-485/Modbus communication, and an optional 2-point measurement configuration are standard or available features. The CODA-500 is footprint-compatible with the former CODA-200 series.

Key Features CODA-500

  • Three model variants: CODA-500-A (acidic KMnO₄, JIS K 0806); CODA-500-B (alkaline KMnO₄, chloride-independent); CODA-500-C (acidic + reagent cleaning, up to 100× FS chloride).
  • Reagent consumption reduced to 1/10 vs previous models — ≥1-month reagent replacement interval; option for reagent delivery service eliminates on-site reagent preparation.
  • Wide measurement range: 0–20 mg/L to 0–2000 mg/L (9 preset ranges); optional 2-range configuration.
  • Reproducibility: ±1% FS (0–20 mg/L range); ±2% FS (30–500 mg/L); ±5% FS (1000–2000 mg/L).
  • Potentiometric titration at constant current with micro syringe — high-precision endpoint detection.
  • Silver nitrate bypass option — eliminates AgNO₃ when chloride concentration is low, reducing reagent costs.
  • COD load calculation capability using flow signal input (4–20 mA).
  • Standard I/O: 3 × 4–20 mA outputs; 14 contact outputs; 1 analog input; 9 contact inputs; RS-485/Modbus.
  • Color touch panel LCD; built-in thermal printer (58 mm, auto take-up); 1-year data memory; USB export.
  • Optional: 2-point measurement; 2 ranges; 6 analog / 21 contact outputs; RS-232C.
  • Footprint-compatible with former CODA-200 series — drop-in replacement at existing installations.

Applications

The CODA-500 is suited to continuous automatic COD monitoring at industrial wastewater discharge points subject to Total Pollutant Load Control regulations — including chemical, food and beverage, pulp and paper, textile, and other industrial facilities discharging to closed water areas — where on-line JIS-method COD measurement is required for regulatory compliance and load reporting.

Installation and Safety Notes

Install indoors on a flat, stable, vibration-free surface at 2–40 °C; avoid dust, mist, corrosive gases, direct sunlight. Power: 100–240 V AC ±10%, 50/60 Hz; 250–350 VA. Sample flow rate: 0.5–5 L/min via overflow tank (optional). Sample temperature 2–40 °C. Blank water: waterworks water (hardness ≤100 mg/L); pressure 100–500 kPa; consumption 20–420 mL per run. Use HORIBA-designated reagents only. Before operation, conduct manual JIS K 0102 analysis and enter the conversion factor. Piping length from main unit to sampling point: within 3 m.

Technical Specifications

Parameter COD (Chemical Oxygen Demand)
Measurement method CODA-500-A/C: Acid KMnO₄ at 100 °C (JIS K 0806); CODA-500-B: Alkaline KMnO₄ at 100 °C
Titration method Potentiometric titration at constant current; micro syringe
Heating method Direct heating at 100 °C
Measurement ranges 0–20 / 30 / 40 / 50 / 100 / 200 / 500 / 1000 / 2000 mg/L (actual upper limit: half-scale)
Reproducibility ±1% FS (0–20 mg/L); ±2% FS (30–500 mg/L); ±5% FS (1000–2000 mg/L)
Zero / Span drift (24 h) ±3% FS (0–20 mg/L); ±4% FS (30–500 mg/L); ±5% FS (1000–2000 mg/L)
Measurement interval 60 minutes
Chloride tolerance (acidic method) CODA-500-A: ≤1× FS; CODA-500-C (with cleaning): ≤100× FS
Measurement points Standard: 1; Optional: 2
Measurement ranges Standard: 1; Optional: 2
Analog outputs Standard: 3 × 4–20 mA DC; Optional: 6 points; max. load 900 Ω; COD concentration, COD load, flow rate
Contact outputs Standard: 14; Optional: 21; 250 V AC / 30 V DC, 3 A; status + alarm
Analog input Standard: 1 × 4–20 mA DC (flow signal); Optional: 1 V–5 V DC
Contact inputs Standard: 9; Optional: 17; no-voltage a-contact (open collector)
Communication RS-485 (standard); RS-232C (optional); Modbus protocol
Display Color LCD touch panel
Printer Built-in thermal printer, 58 mm, with automatic take-up device
Data memory 1 year (measurement values); USB export
Reagent replacement interval ≥1 month
Reagent consumption per run KMnO₄ (A) 2 mL; NaC₂O₄ (B) 1 mL; H₂SO₄ (C) 1 mL; AgNO₃ (D) 0.5 mL (acidic); Na₂S₂O₃ (E) 2 mL (cleaning); NaOH (F) 1 mL (alkaline)
Sample temperature 2–40 °C
Sample flow rate 0.5–5 L/min (via overflow tank)
Blank water consumption 20–420 mL per measurement run
Power supply 100–240 V AC ±10%, 50/60 Hz; 250 VA (100–120 V) / 350 VA (120–240 V)
Operating temperature 2–40 °C
Humidity ≤85% RH (non-condensing)
Installation Indoor; floor-standing
Dimensions (W × D × H) 600 × 510 × 1600 mm
Weight Approx. 150 kg
Backward compatibility Footprint-compatible with CODA-200 series
Manufacturer HORIBA Advanced Techno Co., Ltd.
Brand Horiba