The HE-480C is a compact panel-mount industrial conductivity meter from HORIBA's 48/96 Series, designed for pure water and boiler water control and wastewater treatment monitoring. Using the 2-electrode method with ESD, ESL, ESH, and FS Series sensors across cell constants 0.01, 0.1, and 1.0 /cm, it covers conductivity from sub-μS/cm pure water up to 2000 μS/cm. Temperature compensation includes a dedicated deionised water mode (reference 25 °C) alongside NaCl and arbitrary coefficient options. The panel face carries an IP65 rating; the instrument fits a standard 48 × 96 mm DIN cutout and offers a single isolated 4–20 mA output and two relay contact outputs.
HE-480C, Panel-Mount Type Conductivity Meter, Low Concentration Type, HORIBA
The HE-480C is a panel-mount industrial conductivity meter from HORIBA's 48/96 Series, providing a cost-effective solution for pure water and boiler water control and wastewater treatment monitoring in a compact 48 × 96 mm DIN enclosure. It uses the 2-electrode method and is compatible with the ESD, ESL, ESH, and FS Series sensor lineup across three cell constants, covering the full range from sub-μS/cm ultrapure water to 2000 μS/cm process water. A dedicated deionised water temperature compensation mode (reference temperature 25 °C) ensures accurate measurement in low-conductivity applications, complementing the standard NaCl and user-defined coefficient options. The panel face is rated IP65, and the instrument provides a single isolated 4–20 mA output and two configurable relay contact outputs for alarm and ON/OFF control.
Key Features HE-480C
- 2-electrode method; compatible with ESD, ESL, ESH, and FS Series sensors (cell const. 0.01, 0.1, 1.0 /cm) — covers sub-μS/cm pure water to 2000 μS/cm process water.
- Dedicated deionised water temperature compensation (reference 25 °C), NaCl characteristic, arbitrary coefficient (±5%/°C), or none — selectable per application.
- TDS conversion with user-defined coefficient (0.30–1.00 × conductivity in μS/cm).
- Single isolated 4–20 mA DC output (max. 900 Ω); free range setting; linearity and repeatability ±0.5% FS.
- Two relay contact outputs (SPDT 1c, 240 V AC / 30 V DC, 3 A): R1/R2 selectable as upper/lower limit alarm, ON/OFF control, or maintenance.
- Compact 48 × 96 mm DIN panel-mount format; panel face IP65; ABS case; PBT terminals; Class II device IEC61010-1, Pollution Level 2.
- CE marked: EN61326-1, EN61010-1, RoHS EN50581; FCC Part 15.
Applications
The HE-480C is suited to pure water and boiler water quality control, wastewater treatment monitoring, and general industrial conductivity measurement in panel-integrated control systems where a compact, cost-effective transmitter with standard alarm functions is required.
Installation and Safety Notes
Install into a standard 48 × 96 mm panel cutout. Power: 100–240 V AC, 50/60 Hz, 10 VA max. Panel face IP65; rear case IP20; terminals IP00 — protect the rear of the panel from moisture. Operating temperature −5 to 45 °C; storage −25 to 65 °C; humidity 20–85% RH non-condensing.
Technical Specifications
| Parameter | Conductivity, TDS, Temperature |
| Measurement method | 2-electrode conductivity |
| Compatible sensors | ESD, ESL, ESH, FS Series; cell constants 0.01, 0.1, 1.0 /cm |
| Conductivity range (cell const. 0.01 /cm) | 0–2.000 / 0–20.00 μS/cm |
| Conductivity range (cell const. 0.1 /cm) | 0–20.00 / 0–200.0 μS/cm |
| Conductivity range (cell const. 1.0 /cm) | 0–200.0 / 0–2000 μS/cm |
| Temperature range | 0–100 °C |
| Repeatability / Linearity (conductivity) | Within ±0.5% of full scale |
| Repeatability / Linearity (TDS) | Within ±1.5% of full scale |
| Transmission output | 1 × 4–20 mA DC, isolated; max. 900 Ω; free range setting |
| Contact output | 2 × relay SPDT (1c); 240 V AC / 30 V DC, 3 A; upper/lower alarm, ON/OFF control, maintenance |
| Temperature compensation | Deionised water (ref. 25 °C) / NaCl / arbitrary coefficient ±5%/°C / none; Pt 1 kΩ; range 0–100 °C |
| Power supply | 100–240 V AC, 50/60 Hz, 10 VA max. |
| Operating temperature | −5 °C to 45 °C |
| Storage temperature | −25 °C to 65 °C |
| Humidity | 20–85% RH (non-condensing) |
| Protection rating | Panel face IP65; rear case IP20; terminals IP00 (IEC60529 / JIS C0920) |
| Installation type | Indoor panel-mount (48/96 Series, DIN 48×96 mm) |
| Housing material | ABS (panel case); PBT (terminals) |
| Dimensions (W × H × D) | 48 × 96 × 115 mm (case depth approx. 105 mm) |
| Weight | Approx. 400 g |
| Compliance | CE (EN61326-1, EN61010-1, RoHS EN50581); FCC Part 15; Class II device IEC61010-1; Pollution Level 2 |
| Manufacturer | HORIBA Advanced Techno Co., Ltd. |
| Brand | Horiba |