For phosphonate analysis in water samples from boilers and cooling towers by Color Disc method.
On order
2113301 Phosphonate Test Kit without UV Lamp and Power Supply, Model PN-10
2113301
Hach
Phosphonate Test Set is used for phosphonate determination in the range of 0 - 100 mg/L PO₄³- in water samples from boilers and cooling towers. The set uses Color Disc/ PhosVer 3 method. Model PN-10 may be used to measure up to 100 samples. The smallest increment is 1 mg/L PO₄³-. Phosphonate Test Kit provides testing results in less than 15 minutes.
Phosphonate Test Set contains:
- PhosVer 3 Phosphate Reagent Powder Pillows (p/n 220999)
- Potassium Persulfate Powder Pillows (p/n 2084769)
- 29 mL Square Glass Bottle (p/n 43906)
- Bottle Holder (p/n 1143322)
- Color Comparator Box (p/n 173200)
- Phosphate Color Disc, 0-40 mg/L (p/n 9262100)
- 50 mL Polypropylene Flask, volumetric (p/n 1406041)
- 5 mL Graduated Cylinder (p/n 50837)
- 18 mm Plastic Viewing Tubes, with caps (p/n 4660004)
Procedure for PO₄³- measurement
Before you start take into account the following:
- It is not recommended to use the detergent containing phosphate to clean the labware.
- It is required to wait 4 minutes before starting analysis if the sample temperature is less than 15 °C (59 °F).
- It is necessary to digest the sample for longer time if the sample contains high levels of organic compounds or if the lamp has low power.
- It is recommended to dilute the sample using tap water if deionized water is not available.
Test procedure
- Select the sample volume (see the instructions for detailed information regarding sample volumes and multipliers).
- Use graduated cylinder to measure the sample if the volume of the sample is less than 50 mL.
- Add the sample to the volumetric flask, dilute to the mark with deionized water, install the stopper and invert to mix.
- Mix the sample and Potassium Persulfate Powder Pillow in the bottle, insert in the bottle holder and set the bottle holder in the storage case.
- Put on the UV protection goggles, place the UV lamp in the bottle and switch on the UV lamp. After 10-15 minutes, turn off the UV lamp.
- Fill two tubes to the 5 mL line with the digested sample.
- Place the first tube into the left opening of the color comparator box.
- Pour the content of PhosVer 3 Phosphate Reagent Powder Pillow to the second tube and swirl to mix. The blue color develops as the result of the reaction.
- After 2 minutes, install the second tube into the color comparator box. Rotate the color disc to find the matching color.
- Repeat steps 6 to 9 with the undigested sample. Subtract the undigested value from the digested value.
- Multiply the testing results by the multiplier to receive the testing results as mg/L PO₄ (see manual).
- Convert the testing results to phosphonate as mg/L PO₄³- (see the instructions for detailed information regarding phosphonate conversion).
Brand | Hach |
Parameter | Phosphonate |
Measuring range | 0 - 100 mg/L PO₄³- |
Smallest Increments Steps | 1 |
Method | Color Disc/ PhosVer 3 method |
Digestion required | Yes |
Model | PN-10 |
Number of tests | 0 - 100 tests |