On order

DNB147 Ultrasonic anemometer

DNB147 LSI-Lastem

The DNB147 is a professional-grade triaxial ultrasonic anemometer measuring 3D wind vectors (U/V/W), temperature, humidity, pressure, and sonic temperature. With 0.01 m/s resolution, ±1% speed accuracy, and Modbus-RTU output, it delivers laboratory-grade environmental monitoring for meteorology, aviation, and industrial research. Operates at -40°C to 60°C with IP66 protection.

Add to bag

Overview

The DNB147 is a professional-grade triaxial ultrasonic anemometer measuring 3D wind vectors (U/V/W), temperature, humidity, pressure, and sonic temperature. With 0.01 m/s resolution, ±1% speed accuracy, and Modbus-RTU output, it delivers laboratory-grade environmental monitoring for meteorology, aviation, and industrial research. Operates at -40°C to 60°C with IP66 protection.

Detailed Description

Advanced 3D Wind Field Analysis

As LSI LASTEM's flagship ultrasonic sensor, the DNB147 captures complex wind patterns with triaxial ultrasonic transducers. Measures azimuth (0–360°), elevation (±60°), gusts, and turbulence intensity—critical for wind turbine efficiency studies, pollutant dispersion modeling, and boundary-layer research.

All-in-One Meteorological Station

Beyond wind vectors, integrated Pt100 thermometers, capacitive humidity sensors, and piezoresistive barometers provide comprehensive microclimate data. The magnetic compass auto-corrects directional alignment, while 250ms response time detects microbursts and shear events missed by mechanical sensors.

Key Advantages

  • Triaxial wind measurement: U/V/W vectors + sonic temperature
  • ±1° directional accuracy with configurable 0.2 m/s threshold
  • Integrated environmental sensors: temp, RH%, pressure
  • Zero moving parts—immune to icing, corrosion, and wear
  • Modbus-RTU protocol for SCADA/BMS integration

Technical Specifications

Parameter Value
Order number DNB147
Wind speed range 0–70 m/s
Wind speed accuracy ±1% of value
Wind direction range Azimuth: 0–360°
Elevation: ±60°
Direction accuracy ±1°
Temperature range -40°C to 60°C (Pt100)
RH% accuracy ±2.5% @23°C
Pressure accuracy ±0.4 mbar @20°C
Output Modbus-RTU
Power supply 12–30V DC
Consumption 110 mA @12V
Protection IP66
Mounting Ø 50 mm pole (DNB192 adapter)

Usage Guidelines

Installation & Calibration

Mount vertically using DNB192 adapter. Ensure 10m clearance from obstacles. Use MG2272 12-pin connector with factory-supplied 10m cable. Compass auto-calibrates at startup—avoid magnetic interference.

Data Integration

Configure Modbus registers for: - Instantaneous U/V/W vectors - 3-second gust peaks - Sonic virtual temperature - Compensated pressure/RH% For ISO17025 calibration (SVACA2216), validate annually.

Measuring range 0–75 m/s
Brand LSI-Lastem