Hydro-Optic UV System performs automated dose control, UVT monitoring and water stream disinfection.
RZM350-5 Hydro-Optic Water Disinfection System is developed for real-time water stream monitoring and delivery of the required UV dose. With five high intensity medium pressure UV lamp and total internal reflection from the walls of the quartz reactor, RZM350-5 provides cost-efficient and environmentally friendly water treatment. UV lamps provide broad-spectrum cold and warm water disinfection exposing bacteria, viruses and protozoa to the germicidal wavelengths of the UV light. Total Internal Reflection (TIR) recycles UV light energy in the disinfection chamber providing higher UV dose with minimum energy consumption. Thick quartz tubes separate UV lamps from the water chamber to eliminate the risk of water contamination. The customized control provides user-friendly integration with plant controls and remote monitoring.
Atlantium RZM350-5 Hydro-Optic System includes:
- Disinfection unit
- Ballast module
- Controller
Operating conditions
The maximum water temperature with switched-on lamps is 60 °C (140 °F). The maximum water temperature with switched-off lamps is 90 °C (194 °F). The maximum ambient temperature is 45 °C (113 °F). The maximum working pressure is 7 bar (102 PSI).
Brand | Atlantium Technologies |
Number of lamps | 5 |
Unit Length (mm/inch) | 1635 / 64.4 |
Unit Weight (kg/lb) | 451 / 994 |
Unit volume (liter/gallon) | 197 / 52 |
Unit chamber width at widest point (mm/inch) | 1293 / 50.9 |
Standard pipe connection options | Flange DIN2576 DN350 |
Operating water temperature | 0-60°C / 32-140°F |
Maintenance water temperature | 0-90°C / 32-194°F |
Maximum ambient temperature | 45°C / 113°F |
Maximum Flow Rate | Application dependent |
Maximum working pressure | 7 bar / 102 PSI |
Disinfection chamber material | High grade fused silica (quartz) |
Housing material | Electro-polished stainless steel 316L / Super duplex |
Controller | Integrated, with flat touch screen user interface, remote monitoring and control optional |
Electricity requirements | 200 / 380 / 400 / 440 / 480 / 600 / VAC 3 phases 50/60 Hz |