Hydro-Optic UV System performs automated dose control, UVT monitoring and water stream disinfection.
RZ163-13 is an enhanced system of the RZ163-11 Hydro-Optic UV System. With three high intensity medium pressure UV lamps and total internal reflection from the walls of the quartz reactor, the system reflects UV light back into the water and ensures homogenous UV dose distribution. MPHI lamps emit a broad germicidal spectrum providing complete protection against microorganisms. MPHI lamps are protected by HOD quartz sleeve that is five times thicker than conventional UV sleeve. Lamp replacement can be safely performed during system operation. The real-time monitoring system evaluates HOD UV lamp output and automatically delivers the required UV dose. The customized control provides user-friendly integration with plant controls, remote monitoring and alarm settings for general, UVT, dose out.
Atlantium RZ163-13 Hydro-Optic System includes:
- Disinfection unit
- Ballast module
- Controller
Operating conditions
The recommended operating water stream temperature is from 0°C to 60°C (32-140°F). The required maintenance water temperature is from 0 °C to 90 °C (32-194 °F). The maximum ambient temperature is 45 °C (113 °F). The maximum working pressure is 10 bar (145 PSI).
Brand | Atlantium Technologies |
Number of lamps | 3 |
Max Power Consumption (lamp only) | 5.1 kW |
Unit Length (mm/inch) | 1527 / 60.12 |
Unit Weight (kg/lb) | 125 / 276 |
Unit volume (liter/gallon) | 35 / 9.2 |
Unit chamber width at widest point (mm/inch) | 435 / 17.13 |
Required service clearance on sides (mm/inch) | 750 / 29.53 |
Minimum Height above floor (mm/inch) | 750 / 29.53 |
Standard pipe connection options | DIN2576 DN150 PIN16 ANSI B 16.5 4” 150lb |
Operating water temperature | 0-60°C / 32-140°F |
Maintenance water temperature | 0-90°C / 32-194°F |
Maximum ambient temperature | 45°C / 113°F |
Maximum Flow Rate | Application dependent |
Maximum working pressure | 10 bar / 145 PSI |
Disinfection chamber material | High grade fused silica (quartz) |
Housing material | Electro-polished stainless steel 316L |
Controller | Integrated, with flat touch screen user interface, remote monitoring and control optional |
Electricity requirements | 400VAC 3 phases / 440VAC 3 phases / 480VAC 3 phases |
-
Atlantium Patent Portfolio.pdfdownload