Hydro-Optic UV System performs automated dose control, UVT monitoring and water stream disinfection.
RZ163-11 Hydro-Optic Water Disinfection System is engineered to guarantee biosecurity and reduce energy consumption. Patented Hydro-Optic engineering optimizes UV efficiency with high intensity medium pressure UV lamp, longer UV light paths and optimal water flow. MPHI lamps deliver broad spectrum disinfection. Thick quartz tube separates lamp from water chamber significantly reducing the risk of breakage. RZ163-11 is effective and cost-efficient in cold and warm water stream disinfection. The real-time monitoring system automatically adjusts UV dose and displays real-time data status. New waterproof ballast model provides maximum flexibility and simple maintenance access.
Atlantium RZ163-11 Hydro-Optic System includes:
- Disinfection unit
- Ballast module
- Controller
Operating conditions
The recommended operating water stream temperature is from 0°C to 60°C (32-140°F). The required maintenance water temperature is from 0 °C to 90 °C (32-194 °F). The maximum ambient temperature is 45 °C (113 °F). The maximum working pressure is 10 bar (145 PSI).
Brand | Atlantium Technologies |
Number of lamps | 1 |
Max Power Consumption (lamp only) | 1.7 kW |
Unit Length (mm/inch) | 822 / 32.4 |
Unit Weight (kg/lb) | 57 / 125 |
Unit volume (liter/gallon) | 17.5 / 4.6 |
Unit chamber width at widest point (mm/inch) | 435 / 17.13 |
Required service clearance on sides (mm/inch) | 750 / 29.53 |
Minimum Height above floor (mm/inch) | 750 / 29.53 |
Standard pipe connection options | DIN2576 DN150 PIN16 ANSI B 16.5 4” 150lb |
Operating water temperature | 0-60°C / 32-140°F |
Maintenance water temperature | 0-90°C / 32-194°F |
Maximum ambient temperature | 45°C / 113°F |
Maximum Flow Rate | Application dependent |
Maximum working pressure | 10 bar / 145 PSI |
Disinfection chamber material | High grade fused silica (quartz) |
Housing material | Electro-polished stainless steel 316L |
Controller | Integrated, with flat touch screen user interface, remote monitoring and control optional |
Electricity requirements | 400VAC 3 phases / 440VAC 3 phases / 480VAC 3 phases |
-
Atlantium Patent Portfolio.pdfdownload