On order

RS104 Hydro-Optic UV System

RS104 Atlantium Technologies

Hydro-Optic UV System performs automated dose control, UVT monitoring and water stream disinfection.

Add to bag

RS104 Hydro-Optic Water Disinfection System is developed using the fiber-optic system technology. The system is equipped with one high intensity medium pressure UV lamp that provides cost-efficient and environmentally friendly water treatment. UV lamp disables DNA proteins involved in the cell repair of bacteria, viruses and protozoa. RS104 Hydro-Optic UV System features excellent performance in cold and warm water. UV lamp is separated from the water chamber by high grade silica quartz tube that is five times thicker than conventional UV sleeve. The first integrated sensor monitors UV lamp intensity. The second integrated sensor evaluates the water clarity. The monitoring system automatically adjusts UV dose to changes in real-time conditions, displays real-time data status, and tracks dose and validation parameters.

Atlantium RS104 Hydro-Optic System includes:

  • Disinfection unit
  • Ballast module
  • Controller

Operating conditions

The maximum water temperature with switched-on lamps is 60 °C (140 °F). The maximum water temperature with switched-off lamps is 90 °C (194 °F). The maximum ambient temperature is 45 °C (113 °F). The maximum working pressure is 10 bar (145 PSI).

Brand Atlantium Technologies
Number of lamps 1
Max Power Consumption (lamp only) 1.1 kW
Length of lamp (mm/inch) 262.8 / 10.35
Unit Length (mm/inch) 287 / 11.3
Unit Weight (kg/lb) 22.4 / 49.4
Unit volume (liter/gallon) 2.29 / 0.52
Unit chamber width at widest point (mm/inch) 405 / 16
Required service clearance on sides (mm/inch) 320 / 12.6
Minimum Height above floor (mm/inch) 700 / 27.6
Standard pipe connection options Flange DIN 2527 DN100 PN16 Flange ANSI B 16.5 4” 150lb Tri-Clamp FERRULE DIN 32676 DN 100
Operating water temperature 0-60°C / 32-140°F
Maintenance water temperature 0-90°C / 32-194°F
Maximum ambient temperature 45°C / 113°F
Maximum Flow Rate Application dependent
Maximum working pressure 10 bar / 145 PSI
Disinfection chamber material High grade fused silica (quartz)
Housing material Electro-polished stainless steel 316 / Super duplex
Controller Integrated, with flat touch screen user interface, remote monitoring and control optional
Electricity requirements 400VAC 3 phases / 440VAC 3 phases / 480VAC 3 phases